<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>al</ParameterFamily>
<LongName>
pos_to_rotate_sensor
</LongName>
<Name>
prs
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_400/800_Auto</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
When set, (1), this flag enables the unload traveller rotate position sensor.
This sensor is used to verify that the unload table traveller is in the correct
(i.e. safe) location to rotate the plate. When cleared, (0), the sensor is
by-passed and timeouts are used instead.
</text></DescriptionText>
</Description>
<Type>
byte
</Type>
<Default>
<UnnumberedList>
<li>1</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 1</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
If this flag is cleared, (0), machine operation is significantly slowed down and
some critical safety checks are not done. Clearing this flag should only be done
on a temporary basis and the sensor should be repaired as soon as possible.
Please do not clear this flag unless absolutely necessary!
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../commands/table.xml</LinkAddress><LinkTitle>Command: table</LinkTitle></Link></li>
<li><Link><LinkAddress>../nvs/alpos_cal_crp.xml</LinkAddress><LinkTitle>NVS: alpos crp</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:35:41 2008 PST
</Updated>
<Links>
</Links>
</Parameter>